GDPR

projektai-lsd Lithuanian Standards Board
Portal for draft standards
Comment end date 2025-08-07
Export comments

Project stage codes

1. Prioritetinių darbo temų pažymėjimas ir ekspertų skyrimas
2. Projektas
3. Viešoji apklausa
From 2025-06-08 till 2025-08-07
4. Closure of enquiry
5. Submission to Formal Vote

Organisation

CEN Europos standartizacijos komitetas

ICS

19.100 - Non-destructive testing

Technical Committee

TK 66 Non-destructive testing

ForeignTC'S

CEN/TC 138

Number of comments

0

Comment start date

2025-06-08

Scope

This document specifies a test procedure for determination of the size of industrial radiographic gamma sources of 0,5 mm or greater, made from the radionuclides Iridium 192, Ytterbium 169, Selenium 75 or Cobalt 60, by a radiography method with X-rays. The source size of a gamma radiation source is an important factor which affects the image quality of gamma ray images. The source size is determined with an accuracy of ±10 % but typically not better than ±0,1 mm. The source size is provided by the manufacturer as the mechanical dimension of the source insert. A measurement can be required if the manufacturing process is validated or monitored after implementation of the source into the holder. This document can be used for other radionuclides after validation. The standard test method ASTM E1114 provides further information on the measurement of the Ir-192 source size, the characterization of the source shape, and its correct assembly and packaging.

Relations

Pakeis
LST EN 12679:2019