prEN ISO 1628-2
Plastics - Determination of the viscosity of polymers in dilute solution using capillary viscometers - Part 2: Poly(vinyl chloride) resins (ISO/DIS 1628-2:2026)
Draft New
Comment end date
2026-08-25
Export comments
Project stage codes
1. Prioritetinių darbo temų pažymėjimas ir ekspertų skyrimas
2. Projektas
3. Viešoji apklausa
From 2026-06-26
till 2026-08-25
4. Closure of enquiry
5. Submission to Formal Vote
Organisation
CEN Europos standartizacijos komitetasICS
83.080.20 - Thermoplastic materialsTechnical Committee
TK 68 PlasticsForeignTC'S
CEN/TC 249Number of comments
0Comment start date
2026-06-26Scope
1.1 This document specifies conditions for the determination of the reduced viscosity (also known as viscosity number) and K-value of PVC resins. It is applicable to resins in powder form which consist of homopolymers of the monomer vinyl chloride and copolymers, terpolymers, etc., of vinyl chloride with one or more other monomers, but where vinyl chloride is the main constituent. The resins can contain small amounts of unpolymerized substances (e.g. emulsifying or suspending agents, catalyst residues, etc.) and other substances added during the course of the polymerization. This document is not applicable, however, to resins having a volatile-matter content in excess of 0,5 % ± 0,1 %, when determined in accordance with ISO 1269:2006. In addition to this, it is not applicable to resins which are not entirely soluble in cyclohexanone. 1.2 The reduced viscosity and K-value of a particular resin are related to its molecular mass, but the relationship varies depending on the concentration and type(s) of other monomer(s) present. Hence, homopolymers and copolymers having the same reduced viscosity or K-value can have different molecular masses. 1.3 The values determined for reduced viscosity and K-value, for a particular sample of PVC resin, are influenced differently by the concentration of the solution chosen for the determination. Hence the use of the procedures specified in this document only gives values for reduced viscosity and K-value that are comparable when the concentrations of the solutions used are identical. 1.4 The experimental procedures specified in this document can also be used to characterize the polymeric fraction obtained during the chemical analysis of a PVC composition. However, the values calculated for the reduced viscosity and K-value in these circumstances can deviate form the correct values for the resin used to produce the composition because of the impure nature of the recovered polymer fraction.Relations
Pakeis