prEN 3475-603
Aerospace series - Cables, electrical, aircraft use - Test methods - Part 603: Resistance to wet arc tracking
Draft Public enquiryProject stage codes
1. Decision on WI Proposal
2. Projektas
3. Viešoji apklausa
From 2024-10-27
till 2024-12-21
4. Closure of enquiry
5. Submission to Formal Vote
Organisation
CEN Europos standartizacijos komitetasICS
49.060 - Aerospace electric equipment and systemsForeignTC'S
ASD-STANNumber of comments
0Comment start date
2024-10-27Scope
This document specifies a method of assessing the behaviour of cable insulation subject to an electric arc initiated and maintained by contaminating fluid along the surface of the insulation. This document is intended to be used together with EN 3475-100. The primary aim of this test is: - to produce, in a controlled fashion, continuous failure effects, which are representative of those, which can occur in service when a typical cable bundle is damaged and subjected to aqueous fluid contamination. Electrical arcing occurs along the surface of the insulation between damage sites on adjacent cables; - to examine the aptitude of the insulation to track, to propagate electric arc to the electrical origin. Originally defined for 115 VAC network, this test also proposes conditions for 230 VAC network. However, for 230 VAC test condition only, the test EN 3475-605 can overrule and be applied as test governance as it has been demonstrated that test EN 3475-605 is more stringent, repeatable and reproductible. Unless otherwise specified in the product standard, only 115 VAC conditions are satisfied. Six levels of prospective fault current have been specified for concerned cable sizes (see Clause 8). It is agreed that sizes larger than 051 need not be assessed since the short-circuit phenomenon becomes dominant at low line impedances. Unless otherwise specified in the technical/product standard, sizes 002, 006 and 020 cable are assessed.Relations
Pakeis