prEN ISO 22125-2
Vandens kokybė. Technecis 99. 2 dalis. Tyrimo metodas taikant induktyviai sužadintos plazmos masių spektrometriją (ICP-MS) (ISO/DIS 22125-2:2026)
Standarto projektas NaujasProjekto etapai
1. Prioritetinių darbo temų pažymėjimas ir ekspertų skyrimas
2. Projektas
3. Viešoji apklausa
Nuo 2026-07-16
iki 2026-09-16
4. Closure of enquiry
5. Submission to Formal Vote
Organizacija
CEN Europos standartizacijos komitetasICS
17.240 - Spinduliuotės matavimasTechnikos komitetas
TK 36 Aplinkos apsaugaUžsienio technikos komitetas
CEN/TC 230Komentarų skaičius
0Komentavimo pradžia
2026-07-16Taikymo sritis
Warning — Persons using this document should be familiar with normal laboratory practice. This document does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health practices. Warning — It is absolutely essential that tests conducted in accordance with this document be carried out by suitably qualified staff. This document specifies methods to determine 99Tc by inductively coupled plasma mass spectrometry (ICPMS) in supply water, drinking water, rainwater, surface and ground water, marine water, as well as cooling water, industrial water, domestic, and industrial wastewater after proper sampling, handling, and test sample preparation. The detection limit depends on the sample volume, the instrument used, the background count rate, the detection efficiency, the counting time, and the chemical yield. The detection limit of the methods described in this document, using currently available ICP-MS instrumentation, is approximately 0,2 ng·l−1 to 0,5 ng·l−1 (0,1 Bq·l−1 to 0,3 Bq·l−1), which is much lower than the WHO criteria for safe consumption of drinking water (100 Bq·l−1)[4]. The methods presented in this document are not intended for the determination of ultratrace amount of 99Tc. The methods described in this document are applicable in the event of an emergency situation, but not if 99mTc is present at quantities that could cause interference. Filtration of the test sample is necessary for the methods described in this document if suspended solids are present. The analysis of 99Tc adsorbed to suspended matter is not covered by this method. The analysis of the insoluble fraction requires a mineralization step that is not covered by this document. In this case, the measurement is made on the different phases obtained. It is the user’s responsibility to ensure the validity of this test method for the water samples tested.Ryšiai
Pakeis