prEN IEC 61009-2-1:2026/prAA:2026 Archived
Comment end date 2026-04-08
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 2-1: RCBOs according to classification 4.1.1

IEC 61009-1:2024, Clause 1 is applicable except for the first paragraph and the last paragraph, which are replaced by the following, respectively: This document applies to residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (hereafter referred to as RCBOs), classified according to IEC 61009-1:2024, 4.1.1. RCBOs according to this document are intended for voltages not exceeding 440 V AC with frequencies of 50 Hz, 60 Hz or 50/60 Hz and currents not exceeding 125 A and rated short-circuit capacities not exceeding 25 000 A for operation at 50 Hz or 60 Hz. This document applies in conjunction with IEC 61009-1:2024. It specifies requirements, tests and test sequences to verify compliance and is used for certification purposes.

prEN IEC 61008-1:2026/prAA:2026 Archived
Comment end date 2026-04-08
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules

This document gives general requirements and tests for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (hereafter referred to as RCCBs), for rated operational voltages not exceeding 440 V AC, with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A, intended principally for protection against shock hazard. RCCBs are intended to provide fault protection (previously referred to as protection against indirect contact), the exposed conductive parts of the installation being connected to an appropriate earth electrode. They are also intended to be used to provide protection against fire hazards due to a persistent earth fault current. RCCBs having a rated residual operating current not exceeding 30 mA are used for fault protection and additional protection in the case of failure of the protective provisions against electric shock. This document applies to RCCBs performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. RCCBs are intended to be operated by ordinary or uninstructed persons and designed not to require maintenance. The requirements of this document apply for standard conditions (see 7.1). Additional requirements can be necessary for RCCBs used in locations which have severe environmental conditions. RCCBs within the scope of this document are intended for use in an environment with pollution degree 2 (see 7.3) and overvoltage category III. RCCBs are suitable for isolation. Special precautions (e.g. surge protective devices) can be necessary when excessive overvoltages are likely to occur on the supply side (for example in the case of supply through overhead lines, see IEC 60364-4-44 and IEC 60364-5-53). RCCBs are suitable for use in IT systems. RCCBs of the general type are resistant to current surges, including the case where surge voltages (as a result of switching transients or induced by lightning) cause loading currents in the installation without occurrence of flashover. RCCBs of type S are considered to be sufficiently resistant against unwanted tripping even if the surge voltage causes a flashover and a follow-on current occurs. Particular requirements are necessary for RCCBs intended to be used at frequencies other than 50 Hz or 60 Hz. For RCCBs incorporated in, or intended for association with socket-outlets only, the requirements of this document can be used, as far as applicable, in conjunction with the requirements of IEC 60884-1 or the national requirements of the country where the product is placed on the market. This document does not apply to: – RCCBs the current setting of which is adjustable without a tool; – RCCBs including batteries. This document is not intended to be used alone; it is intended to be used in conjunction with the relevant product standard, IEC 61008-2-1 or IEC 61008-2-2.

prEN IEC 61009-2-1:2026 Archived
Comment end date 2026-04-08
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 2-1: RCBOs according to classification 4.1.1

IEC 61009-1:2024, Clause 1 is applicable except for the first paragraph and the last paragraph, which are replaced by the following, respectively: This document applies to residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (hereafter referred to as RCBOs), classified according to IEC 61009-1:2024, 4.1.1. RCBOs according to this document are intended for voltages not exceeding 440 V AC with frequencies of 50 Hz, 60 Hz or 50/60 Hz and currents not exceeding 125 A and rated short-circuit capacities not exceeding 25 000 A for operation at 50 Hz or 60 Hz. This document applies in conjunction with IEC 61009-1:2024. It specifies requirements, tests and test sequences to verify compliance and is used for certification purposes.

prEN IEC 61008-2-1:2026 Archived
Comment end date 2026-04-08
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 2-1: RCCBs according to classification 4.1.1

IEC 61008-1:2024, Clause 1 is applicable except for the first paragraph, which is replaced by the first paragraph below, and the last paragraph, which is replaced by the second paragraph below: This part of IEC 61008 applies to residual current operated circuit-breakers, without integral overcurrent protection, for household and similar uses (hereafter referred to as RCCBs), classified according to IEC 61008-1:2024, 4.1.1. RCCBs according to this document are intended for voltages not exceeding 440 V AC with frequencies of 50 Hz, 60 Hz or 50/60 Hz and currents not exceeding 125 A, intended principally for protection against shock hazard. This document applies in conjunction with IEC 61008-1:2024. It specifies requirements, tests and test sequences to verify compliance and is used for certification purposes.

prEN IEC 61009-1:2026 Archived
Comment end date 2026-04-08
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules

This document gives general requirements and tests for residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (hereafter referred to as RCBOs), for rated operational voltages not exceeding 440 V AC, with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A and rated short-circuit capacities not exceeding 25 000 A. RCBOs are intended to provide fault protection (previously referred to as protection against indirect contact), the exposed conductive parts of the installation being connected to an appropriate earth electrode. These devices are also intended to protect against overcurrents in the wiring installations of buildings and similar applications. They are also intended to be used to provide protection against fire hazards due to a persistent earth fault current. RCBOs having a rated residual operating current not exceeding 30 mA are used for fault protection and additional protection in the case of failure of the protective provisions against electric shock. This document applies to RCBOs performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. These devices also perform the function of making, carrying and breaking overcurrents under specified conditions. RCBOs are intended to be operated by ordinary or uninstructed persons and designed not to require maintenance. The requirements of this document apply for standard conditions (see 7.1). Additional requirements can be necessary for RCBOs used in locations which have severe environmental conditions. RCBOs within the scope of this document are intended for use in an environment with pollution degree 2 (see 7.3). RCBOs are suitable for isolation. Special precautions (e.g. surge protective devices) can be necessary when excessive overvoltages are likely to occur on the supply side (for example in the case of supply through overhead lines, see IEC 60364-4-44 and IEC 60364-5-53). RCBOs, with the exception of those with an uninterrupted neutral, are suitable for use in IT systems. RCBOs of the general type are resistant to current surges, including the case where surge voltages (as a result of switching transients or induced by lightning) cause loading currents in the installation without occurrence of flashover. RCBOs of type S are considered to be sufficiently resistant against unwanted tripping even if the surge voltage causes a flashover and a follow-on current occurs. This document also applies to RCBOs obtained by the assembly of an adaptable residual current device with a circuit-breaker. The mechanical assembly is intended to be effected in the factory by the manufacturer, or on site, in which case the requirements of Annex G apply. It also applies to RCBOs having more than one rated current, provided that the means for changing from one discrete rating to another is not accessible in normal service and that the rating cannot be changed without the use of a tool. Particular requirements are necessary for RCBOs intended to be used at frequencies other than 50 Hz or 60 Hz. For RCBOs incorporated in, or intended for association with socket-outlets only, the requirements of this document can be used, as far as applicable, in conjunction with the requirements of IEC 60884-1 or the national requirements of the country where the product is placed on the market. This document does not apply to: .........

prEN IEC 61008-1:2026 Archived
Comment end date 2026-04-08
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules

This document gives general requirements and tests for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (hereafter referred to as RCCBs), for rated operational voltages not exceeding 440 V AC, with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A, intended principally for protection against shock hazard. RCCBs are intended to provide fault protection (previously referred to as protection against indirect contact), the exposed conductive parts of the installation being connected to an appropriate earth electrode. They are also intended to be used to provide protection against fire hazards due to a persistent earth fault current. RCCBs having a rated residual operating current not exceeding 30 mA are used for fault protection and additional protection in the case of failure of the protective provisions against electric shock. This document applies to RCCBs performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. RCCBs are intended to be operated by ordinary or uninstructed persons and designed not to require maintenance. The requirements of this document apply for standard conditions (see 7.1). Additional requirements can be necessary for RCCBs used in locations which have severe environmental conditions. RCCBs within the scope of this document are intended for use in an environment with pollution degree 2 (see 7.3). RCCBs are suitable for isolation. Special precautions (e.g. surge protective devices) can be necessary when excessive overvoltages are likely to occur on the supply side (for example in the case of supply through overhead lines, see IEC 60364-4-44 and IEC 60364-5-53). RCCBs, with the exception of those with an uninterrupted neutral, are suitable for use in IT systems. RCCBs of the general type are resistant to current surges, including the case where surge voltages (as a result of switching transients or induced by lightning) cause loading currents in the installation without occurrence of flashover. RCCBs of type S are considered to be sufficiently resistant against unwanted tripping even if the surge voltage causes a flashover and a follow-on current occurs. Particular requirements are necessary for RCCBs intended to be used at frequencies other than 50 Hz or 60 Hz. For RCCBs incorporated in, or intended for association with socket-outlets only, the requirements of this document can be used, as far as applicable, in conjunction with the requirements of IEC 60884-1 or the national requirements of the country where the product is placed on the market. This document does not apply to: – RCCBs the current setting of which is adjustable without a tool; – RCCBs including batteries. This document is not intended to be used alone; it is intended to be used in conjunction with the relevant product standard, IEC 61008-2-1 or IEC 61008-2-2.

Quick filters

Technical Committee
TK 1 Electronics (5) TK 4 Information technology (1) TK 5 Electrical engineering (19) TK 12 Motor - roads (1) TK 13 Agricultural engineering (8) TK 18 Telecommunications (11) TK 19 Concrete and reinforced concrete (1) TK 20 Toys, child use articles, sports and other recreational equipment (1) TK 21 Textiles and personal protective equipment (1) TK 22 Fire safety (1) TK 23 Ceramic tiles, masonry and natural stones (2) TK 28 Gas systems (5) TK 29 Water supply (1) TK 32 Health (20) TK 33 Fishery (2) TK 34 Metrology (1) TK 35 Safety of machinery (3) TK 36 Environmental protection (8) TK 38 Building constructions (11) TK 39 Protection (1) TK 40 Petroleuml, petroleum products, lubricants and alternative fuels (3) TK 41 Welding (3) TK 42 Packaging (1) TK 43 Railway traffic (2) TK 45 Electric power (17) TK 47 Information and documentation (1) TK 49 Metallic materials (6) TK 50 Heating and Ventilation Systems (1) TK 51 Food analysis- Horizontal methods (2) TK 54 Assistive products for persons with disability (1) TK 57 Fertilizers (21) TK 59 Geotechnics (1) TK 60 Windows and doors (1) TK 63 Gas cylinders and cryogenic vessels (3) TK 64 Ergonomics (1) TK 66 Non-destructive testing (2) TK 68 Plastics (3) TK 70 Pulp, paper, board, adhesives (6) TK 76 Explosive atmospheres (2) TK 79 IT security techniques (6) TK 82 Safety of trackless overground vehicles (1) TK 87 Biotechnology (1) TK 88 Building Information Modelling (BIM) (3) TK 89 Risk management and organizational governance (1) TK 91 Asset management and technical maintenance (1) TK 92 Public Procurement (3) TK 99 Health Informatics (2)
ICS
Dirvožemio kokybė ir dirvotyra. Bendrieji dalykai (1) Žemės ūkis (Žodynai) (2) Adhesives (1) Aerospace electric equipment and systems (1) Agricultural machines and equipment in general (2) Alarm and warning systems (1) Alkaline secondary cells and batteries (2) Aluminium products (2) Aluminium structures (3) Application of information technology in general (1) Binders. Sealing materials (1) Biobased products (1) Biology. Botany. Zoology (1) Body care equipment (1) Bolts, screws, studs (1) Brazing and soldering (1) Bridge construction (1) Cement. Gypsum. Lime. Mortar (1) Check valves (1) Chemical analysis of metals (1) Chemical laboratories. Laboratory equipment (3) Cleaning appliances (2) Construction of railways (1) Cookware, cutlery and flatware (1) Copper products (1) Corrosion of metals (1) Dental equipment (1) Dental instruments (2) Dental materials (5) Dentistry in general (1) Domestic safety (2) Earthworks. Excavations. Foundation construction. Underground works (1) Electric road vehicles (1) Electrical and electronic equipment (1) Electrical and electronic testing (1) Electrical apparatus for explosive atmospheres (2) Electricity supply systems (1) Explosives. Pyrotechnics and fireworks (2) Extraction and processing of petroleum and natural gas (2) Fasteners in general (1) Ferrous alloys in general (1) Fertilizers (18) Fibre optic interconnecting devices (2) Fibres and cables (6) Finances. Banking. Monetary systems. Insurance (1) Fire protection (1) Fish and fishery products (1) Floor coverings (2) Fuses and other overcurrent protection devices (6) Gas cylinders (1) Gas supply systems (1) Gases for industrial application (1) General purpose pallets (1) Geology. Meteorology. Hydrology (1) Geometrical Product Specification (GPS) (2) Glass in building (1) Governance and ethics (1) Harvesting equipment (1) Implants for surgery, prosthetics and orthotics (1) Industrial process measurement and control (1) Information technology (IT) in general (1) Inland navigation vessels (1) Installations and equipment for waste disposal and treatment (1) Iron and steel forgings (1) Iron and steel products in general (1) IT applications in building and construction industry (3) IT applications in health care technology (2) IT applications in trade (2) IT applications in transport (1) IT Security (8) Laboratory medicine in general (1) Laminated sheets (1) Laundry appliances (1) Leather and furs (2) Luminaires (1) Maintenance services. Facilities management (1) Materials for aerospace construction in general (1) Measurement of electrical and magnetic quantities (1) Measurement of volume, mass, density, viscosity (1) Mechanical structures for electronic equipment (2) Mechanical testing of metals (1) Medical equipment in general (1) Medical microbiology (1) Metallurgy (Vocabularies) (1) Mineral materials and products (2) Noise emitted by machines and equipment (2) Non-destructive testing (2) Nuclear power plants. Safety (1) Nuts (2) Organic coatings (1) Other construction materials (4) Other equipment related to power transmission and distribution networks (2) Other products of the chemical industry (1) Other wood-based panels (1) Outdoor and water sports equipment (1) Paints and varnishes (2) Passenger and cabin equipmen (1) Petroleum products in general (3) Plastics in general (1) Plastics pipes and fittings for non fluid use (1) Pollution, pollution control and conservation (4) Power transmission and distribution lines (1) Power transmission and distribution networks in general (1) Product life-cycles (1) Products of the chemical industry (1) Pumps and motors (1) Purchasing. Procurement. Logistics (1) Radiation protection (1) Railway rolling stock in general (1) Raw skins, hides and pelts (1) Rectifiers. Converters. Stabilized power supply (1) Recycling (2) Respiratory protective devices (1) Rotating machinery in general (1) Safety of machinery (5) Screw threads (1) Seismic and vibration protection (1) Semiconductor devices in general (2) Small kitchen appliances (1) Software (1) Solar energy engineering (1) Steel pipes and tubes for specific use (2) Steel structures (1) Steels (1) Sterilizing equipment (1) Switches (1) Syringes, needles and catheters (3) Technical aspects (5) Technical product documentation (1) Telecommunications in general (1) TELECOMMUNICATIONS. AUDIO AND VIDEO ENGINEERING (11) Telecontrol. Telemetering (7) Textile fibres in general (1) Thermistors (1) Trailing stock (1) Transfusion, infusion and injection equipment (3) Ventilators. Fans. Air-conditioners (1) Water heating equipment (2) Welding equipment (2) Welding, brazing and soldering in general (1) Woodworking machines (3) Workplace atmospheres (1) Writing and transliteration (1)