GDPR

projektai-lsd Lithuanian Standards Board
Portal for draft standards

Extended search

till

Results

Showing:
Total records found: 258
arrow-prev 1 2 3 4 5 6 11 arrow-next
prEN IEC 60793-1-50:2026 Public enquiry
Comment end date 2026-04-10
Optical fibres - Part 1-50: Measurement methods and test procedures - Damp heat (steady state) tests
prEN IEC 60793-1-51:2026 Public enquiry
Comment end date 2026-04-10
Optical fibres - Part 1-51: Measurement methods and test procedures - Dry heat (steady state) tests
prEN IEC 60793-1-52:2026 Public enquiry
Comment end date 2026-04-10
Optical fibres - Part 1-52: Measurement methods and test procedures - Change of temperature tests
prEN IEC 61225:2026 Public enquiry
Comment end date 2026-04-10
Nuclear power plants - Instrumentation, control and electrical power systems - Requirements for static uninterruptible DC and AC power supply systems

See the scope of IEC 61225:2025. Adoption is to be implemented without modification.

EN 50440:2015/prA2:2026 Public enquiry
Comment end date 2026-04-10
Efficiency of domestic electrical storage water heaters and testing methods

This European Standard specifies methods for measuring the performance of electric storage water heaters for the production of sanitary hot water for household and similar use. The object is to state and define the principal performance characteristics of electric storage water heaters and to describe the test methods for measuring these characteristics. NOTE 1 This standard does not apply to; − storage water heaters that use electricity as a secondary source of heating the water; − storage water heaters that do not use a tank to store hot water; − electric storage water heaters that do not meet the minimum (or maximum) output performance of the smallest (or biggest) load profile, as defined in Table 4. NOTE 2 This standard does not specify performance or safety requirements. For safety requirements see EN 60335-1:2020 in conjunction with EN 60335-2-21:2023

prEN 50583-1:2026 Public enquiry
Comment end date 2026-04-10
Photovoltaics in buildings - Part 1: BIPV modules

This document applies to photovoltaic modules that contain at least one glass pane and which are used as construction products. It focuses on the properties of these photovoltaic modules relevant to essential building requirements as specified in the European Construction Product Regulation CPR 305/2011, and the applicable electro-technical requirements as stated in the Low Voltage Directive 2014/35/EU / or CENELEC standards. The CE mark of building integrated photovoltaic (BIPV) modules will thus state properties based on both documents as they are both equally applicable. This document references international standards, technical reports and guidelines. For some mounting categories, in addition, national standards (or regulations) for building products may apply in individual countries, which are not explicitly referenced here and for which harmonized European Standards are not yet available. The document is addressed to manufacturers, planners, system designers, installers, testing institutes and building authorities. This document does not address concentrating or building-attached photovoltaic modules (BAPV). This document addresses requirements on the PV modules in the specific ways they are intended to be mounted. Separable mounting structures are within the scope of EN 50583 2. NOTE For the definition of building-attached photovoltaic modules (BAPV) refer to Clause 3.

prEN 16261 Public enquiry
Comment end date 2026-04-09
Pyrotechnic articles - Fireworks, Category F4

This document specifies requirements for the construction, performance, protective packaging and labelling of Category F4 fireworks, as listed in Clauses 4, 5 and 6. This document does not apply to fireworks intended to be kept or used at temperatures below −20 °C or above 50 °C.

prEN ISO 13849-2 Public enquiry
Comment end date 2026-04-09
Safety of machinery - Safety-related parts of control systems - Part 2: Validation (ISO/DIS 13849-2:2026)

This document provides requirements for the application of basic and well-tried safety principles and conditions for possible fault exclusions. This document provides guidance for the design and the validation of mechanical, pneumatic, hydraulic, and electrical systems for the safety-related parts of a control system (SRP/CS) designed in accordance with ISO 13849-1:2023. NOTE Additional requirements for programmable electronic systems, including embedded software, are given in ISO 13849-1:2023, Clause 7, and IEC 61508.

prEN ISO 41012 Public enquiry
Comment end date 2026-04-09
Facility management - Guidance on strategic sourcing and the development of agreements (ISO/DIS 41012:2026)

ISO 41012:2017 provides guidance on sourcing and development of agreements in facility management (FM). It highlights: · essential elements in FM sourcing processes; · FM roles and responsibilities in sourcing processes; · development processes and structures of typical agreement models. ISO 41012:2017 is applicable to: · strategic processes related to service and support functions for the core business; · development of FM strategies; · development of facility service provision agreements covering both public and private service demand and internal and external production/delivery options; · development of FM information systems; · FM education and research; · organization development and business re-engineering processes in major types of working environments (e.g. industrial, commercial, administration, military, healthcare, accommodation).

prEN IEC 61009-2-1:2026/prAA:2026 Public enquiry
Comment end date 2026-04-08
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 2-1: RCBOs according to classification 4.1.1

IEC 61009-1:2024, Clause 1 is applicable except for the first paragraph and the last paragraph, which are replaced by the following, respectively: This document applies to residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (hereafter referred to as RCBOs), classified according to IEC 61009-1:2024, 4.1.1. RCBOs according to this document are intended for voltages not exceeding 440 V AC with frequencies of 50 Hz, 60 Hz or 50/60 Hz and currents not exceeding 125 A and rated short-circuit capacities not exceeding 25 000 A for operation at 50 Hz or 60 Hz. This document applies in conjunction with IEC 61009-1:2024. It specifies requirements, tests and test sequences to verify compliance and is used for certification purposes.

prEN IEC 61008-2-1:2026/prAA:2026 Public enquiry
Comment end date 2026-04-08
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 2-1: RCCBs according to classification 4.1.1

IEC 61008-1:2024, Clause 1 is applicable except for the first paragraph, which is replaced by the first paragraph below, and the last paragraph, which is replaced by the second paragraph below: This part of IEC 61008 applies to residual current operated circuit-breakers, without integral overcurrent protection, for household and similar uses (hereafter referred to as RCCBs), classified according to IEC 61008-1:2024, 4.1.1. RCCBs according to this document are intended for voltages not exceeding 440 V AC with frequencies of 50 Hz, 60 Hz or 50/60 Hz and currents not exceeding 125 A, intended principally for protection against shock hazard. This document applies in conjunction with IEC 61008-1:2024. It specifies requirements, tests and test sequences to verify compliance and is used for certification purposes.

prEN IEC 61009-2-1:2026 Public enquiry
Comment end date 2026-04-08
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 2-1: RCBOs according to classification 4.1.1

IEC 61009-1:2024, Clause 1 is applicable except for the first paragraph and the last paragraph, which are replaced by the following, respectively: This document applies to residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (hereafter referred to as RCBOs), classified according to IEC 61009-1:2024, 4.1.1. RCBOs according to this document are intended for voltages not exceeding 440 V AC with frequencies of 50 Hz, 60 Hz or 50/60 Hz and currents not exceeding 125 A and rated short-circuit capacities not exceeding 25 000 A for operation at 50 Hz or 60 Hz. This document applies in conjunction with IEC 61009-1:2024. It specifies requirements, tests and test sequences to verify compliance and is used for certification purposes.

prEN IEC 61008-2-1:2026 Public enquiry
Comment end date 2026-04-08
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 2-1: RCCBs according to classification 4.1.1

IEC 61008-1:2024, Clause 1 is applicable except for the first paragraph, which is replaced by the first paragraph below, and the last paragraph, which is replaced by the second paragraph below: This part of IEC 61008 applies to residual current operated circuit-breakers, without integral overcurrent protection, for household and similar uses (hereafter referred to as RCCBs), classified according to IEC 61008-1:2024, 4.1.1. RCCBs according to this document are intended for voltages not exceeding 440 V AC with frequencies of 50 Hz, 60 Hz or 50/60 Hz and currents not exceeding 125 A, intended principally for protection against shock hazard. This document applies in conjunction with IEC 61008-1:2024. It specifies requirements, tests and test sequences to verify compliance and is used for certification purposes.

prEN IEC 61009-1:2026/prAA:2026 Public enquiry
Comment end date 2026-04-08
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules

This document gives general requirements and tests for residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (hereafter referred to as RCBOs), for rated operational voltages not exceeding 440 V AC, with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A and rated short-circuit capacities not exceeding 25 000 A. RCBOs are intended to provide fault protection (previously referred to as protection against indirect contact), the exposed conductive parts of the installation being connected to an appropriate earth electrode. These devices are also intended to protect against overcurrents in the wiring installations of buildings and similar applications. They are also intended to be used to provide protection against fire hazards due to a persistent earth fault current. RCBOs having a rated residual operating current not exceeding 30 mA are used for fault protection and additional protection in the case of failure of the protective provisions against electric shock. This document applies to RCBOs performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. These devices also perform the function of making, carrying and breaking overcurrents under specified conditions. RCBOs are intended to be operated by ordinary or uninstructed persons and designed not to require maintenance. The requirements of this document apply for standard conditions (see 7.1). Additional requirements can be necessary for RCBOs used in locations which have severe environmental conditions. RCBOs within the scope of this document are intended for use in an environment with pollution degree 2 (see 7.3). RCBOs are suitable for isolation. Special precautions (e.g. surge protective devices) can be necessary when excessive overvoltages are likely to occur on the supply side (for example in the case of supply through overhead lines, see IEC 60364-4-44 and IEC 60364-5-53). RCBOs, with the exception of those with an uninterrupted neutral, are suitable for use in IT systems. RCBOs of the general type are resistant to current surges, including the case where surge voltages (as a result of switching transients or induced by lightning) cause loading currents in the installation without occurrence of flashover. RCBOs of type S are considered to be sufficiently resistant against unwanted tripping even if the surge voltage causes a flashover and a follow-on current occurs. This document also applies to RCBOs obtained by the assembly of an adaptable residual current device with a circuit-breaker. The mechanical assembly is intended to be effected in the factory by the manufacturer, or on site, in which case the requirements of Annex G apply. It also applies to RCBOs having more than one rated current, provided that the means for changing from one discrete rating to another is not accessible in normal service and that the rating cannot be changed without the use of a tool. Particular requirements are necessary for RCBOs intended to be used at frequencies other than 50 Hz or 60 Hz. For RCBOs incorporated in, or intended for association with socket-outlets only, the requirements of this document can be used, as far as applicable, in conjunction with the requirements of IEC 60884-1 or the national requirements of the country where the product is placed on the market. This document does not apply to: ....

prEN IEC 61008-1:2026/prAA:2026 Public enquiry
Comment end date 2026-04-08
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules

This document gives general requirements and tests for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (hereafter referred to as RCCBs), for rated operational voltages not exceeding 440 V AC, with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A, intended principally for protection against shock hazard. RCCBs are intended to provide fault protection (previously referred to as protection against indirect contact), the exposed conductive parts of the installation being connected to an appropriate earth electrode. They are also intended to be used to provide protection against fire hazards due to a persistent earth fault current. RCCBs having a rated residual operating current not exceeding 30 mA are used for fault protection and additional protection in the case of failure of the protective provisions against electric shock. This document applies to RCCBs performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. RCCBs are intended to be operated by ordinary or uninstructed persons and designed not to require maintenance. The requirements of this document apply for standard conditions (see 7.1). Additional requirements can be necessary for RCCBs used in locations which have severe environmental conditions. RCCBs within the scope of this document are intended for use in an environment with pollution degree 2 (see 7.3) and overvoltage category III. RCCBs are suitable for isolation. Special precautions (e.g. surge protective devices) can be necessary when excessive overvoltages are likely to occur on the supply side (for example in the case of supply through overhead lines, see IEC 60364-4-44 and IEC 60364-5-53). RCCBs are suitable for use in IT systems. RCCBs of the general type are resistant to current surges, including the case where surge voltages (as a result of switching transients or induced by lightning) cause loading currents in the installation without occurrence of flashover. RCCBs of type S are considered to be sufficiently resistant against unwanted tripping even if the surge voltage causes a flashover and a follow-on current occurs. Particular requirements are necessary for RCCBs intended to be used at frequencies other than 50 Hz or 60 Hz. For RCCBs incorporated in, or intended for association with socket-outlets only, the requirements of this document can be used, as far as applicable, in conjunction with the requirements of IEC 60884-1 or the national requirements of the country where the product is placed on the market. This document does not apply to: – RCCBs the current setting of which is adjustable without a tool; – RCCBs including batteries. This document is not intended to be used alone; it is intended to be used in conjunction with the relevant product standard, IEC 61008-2-1 or IEC 61008-2-2.

prEN IEC 61009-1:2026 Public enquiry
Comment end date 2026-04-08
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules

This document gives general requirements and tests for residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (hereafter referred to as RCBOs), for rated operational voltages not exceeding 440 V AC, with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A and rated short-circuit capacities not exceeding 25 000 A. RCBOs are intended to provide fault protection (previously referred to as protection against indirect contact), the exposed conductive parts of the installation being connected to an appropriate earth electrode. These devices are also intended to protect against overcurrents in the wiring installations of buildings and similar applications. They are also intended to be used to provide protection against fire hazards due to a persistent earth fault current. RCBOs having a rated residual operating current not exceeding 30 mA are used for fault protection and additional protection in the case of failure of the protective provisions against electric shock. This document applies to RCBOs performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. These devices also perform the function of making, carrying and breaking overcurrents under specified conditions. RCBOs are intended to be operated by ordinary or uninstructed persons and designed not to require maintenance. The requirements of this document apply for standard conditions (see 7.1). Additional requirements can be necessary for RCBOs used in locations which have severe environmental conditions. RCBOs within the scope of this document are intended for use in an environment with pollution degree 2 (see 7.3). RCBOs are suitable for isolation. Special precautions (e.g. surge protective devices) can be necessary when excessive overvoltages are likely to occur on the supply side (for example in the case of supply through overhead lines, see IEC 60364-4-44 and IEC 60364-5-53). RCBOs, with the exception of those with an uninterrupted neutral, are suitable for use in IT systems. RCBOs of the general type are resistant to current surges, including the case where surge voltages (as a result of switching transients or induced by lightning) cause loading currents in the installation without occurrence of flashover. RCBOs of type S are considered to be sufficiently resistant against unwanted tripping even if the surge voltage causes a flashover and a follow-on current occurs. This document also applies to RCBOs obtained by the assembly of an adaptable residual current device with a circuit-breaker. The mechanical assembly is intended to be effected in the factory by the manufacturer, or on site, in which case the requirements of Annex G apply. It also applies to RCBOs having more than one rated current, provided that the means for changing from one discrete rating to another is not accessible in normal service and that the rating cannot be changed without the use of a tool. Particular requirements are necessary for RCBOs intended to be used at frequencies other than 50 Hz or 60 Hz. For RCBOs incorporated in, or intended for association with socket-outlets only, the requirements of this document can be used, as far as applicable, in conjunction with the requirements of IEC 60884-1 or the national requirements of the country where the product is placed on the market. This document does not apply to: .........

prEN IEC 61008-1:2026 Public enquiry
Comment end date 2026-04-08
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules

This document gives general requirements and tests for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (hereafter referred to as RCCBs), for rated operational voltages not exceeding 440 V AC, with rated frequencies of 50 Hz, 60 Hz or 50/60 Hz and rated currents not exceeding 125 A, intended principally for protection against shock hazard. RCCBs are intended to provide fault protection (previously referred to as protection against indirect contact), the exposed conductive parts of the installation being connected to an appropriate earth electrode. They are also intended to be used to provide protection against fire hazards due to a persistent earth fault current. RCCBs having a rated residual operating current not exceeding 30 mA are used for fault protection and additional protection in the case of failure of the protective provisions against electric shock. This document applies to RCCBs performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. RCCBs are intended to be operated by ordinary or uninstructed persons and designed not to require maintenance. The requirements of this document apply for standard conditions (see 7.1). Additional requirements can be necessary for RCCBs used in locations which have severe environmental conditions. RCCBs within the scope of this document are intended for use in an environment with pollution degree 2 (see 7.3). RCCBs are suitable for isolation. Special precautions (e.g. surge protective devices) can be necessary when excessive overvoltages are likely to occur on the supply side (for example in the case of supply through overhead lines, see IEC 60364-4-44 and IEC 60364-5-53). RCCBs, with the exception of those with an uninterrupted neutral, are suitable for use in IT systems. RCCBs of the general type are resistant to current surges, including the case where surge voltages (as a result of switching transients or induced by lightning) cause loading currents in the installation without occurrence of flashover. RCCBs of type S are considered to be sufficiently resistant against unwanted tripping even if the surge voltage causes a flashover and a follow-on current occurs. Particular requirements are necessary for RCCBs intended to be used at frequencies other than 50 Hz or 60 Hz. For RCCBs incorporated in, or intended for association with socket-outlets only, the requirements of this document can be used, as far as applicable, in conjunction with the requirements of IEC 60884-1 or the national requirements of the country where the product is placed on the market. This document does not apply to: – RCCBs the current setting of which is adjustable without a tool; – RCCBs including batteries. This document is not intended to be used alone; it is intended to be used in conjunction with the relevant product standard, IEC 61008-2-1 or IEC 61008-2-2.

prEN IEC 60730-2-10:2026 Public enquiry
Comment end date 2026-04-08
Automatic electrical controls for household and similar use - Part 2-10: Particular requirements for motor-starting relays
prEN IEC 62364:2026 Public enquiry
Comment end date 2026-04-08
Hydraulic machines - Guidelines for dealing with hydro-abrasive erosion in Kaplan, Francis and Pelton turbines
ISO/IEC 29192-4:2013/DAmd 2 Public enquiry
Comment end date 2026-04-12
Information technology — Security techniques — Lightweight cryptography — Part 4: Mechanisms using asymmetric techniques — Amendment 2
ISO/IEC 18033-7:2022/DAmd 1 Public enquiry
Comment end date 2026-04-12
Information security — Encryption algorithms — Part 7: Tweakable block ciphers — Amendment 1
ISO/IEC 29192-8:2022/DAmd 1 Public enquiry
Comment end date 2026-04-12
Information security — Lightweight cryptography — Part 8: Authenticated encryption — Amendment 1
prEN 18289 Public enquiry
Comment end date 2026-04-07
Ventilation for buildings - Metallic ventilation ducts - Requirements and test methods

This document specifies dimensions, tolerances and denomination for rigid metallic ductwork used for ventilation air conditioning of buildings including test methods and performance characteristics regarding strength and leakage for ductwork, ducts and fittings in laboratory conditions. The test methods, shapes, designs and performance characteristics are applicable for ventilation ducts with circular and rectangular cross sections. The leakage test methods are also applicable to other cross sections. This document does not include ductwork made from insulation duct board, which is covered in EN 13403 [6], non-metallic ductwork, covered in EN 17192 [7] and all components that have more functions than the transport of air for example fire dampers, filter units, air terminal devices handled in EN 1751 [8] and EN 15727 [9]. This document does not include requirements for the overall system design for the air tightness which is covered in EN 16798-3 [10]. On-site tests are given in EN 12599 [11].

prEN 17017-2 Public enquiry
Comment end date 2026-04-07
Electronic Public Procurement - Fulfilment - Part 2: Transactions

This document describes the transaction information requirements of the transactions used in the basic collaborations described in EN 17017-1:2025, Electronic Public Procurement — Fulfillment — Choreographies. For each transaction there is an overview, the transaction business requirements and the transaction information requirements model containing definitions of terms, usage descriptions and cardinality of the information elements. The document describes the following transactions: a) Despatch Advice; b) Receipt Advice. The identifier of this transactions document is CEN/EN 17017-2:20xx. How to claim compliance to a transaction is described in Clause 6.

prEN 17014-2 Public enquiry
Comment end date 2026-04-07
Electronic public procurement - Pre-award - Part 2: Transactions

The document describes the transactions for pre-award processes between Contracting Entities (Buyer) and Economic Operators (Seller), where the Buyer seeks to establish a contract for the procurement of products, services, or works. The various possible behaviours of Buyers and Sellers are represented through choreography variants as described in prEN 17014-2:2025 [7]. This document specifies the transactions described by the choreography variants and captures their specific functional and informational aspects. The transactions are grouped along the following collaborations which are applied in pre-award choreographies: — Procurement procedure subscription — Procurement documents access — Tender submission — Procurement documents questions and answers — Tender clarification — Tender withdrawal — Notify awarding — Tendering message response — Tenderer qualification — Qualification response — Invitation to tender For each transaction, the document specifies the underlying business and information requirements, including the functional and procedural objectives the transaction must fulfil, the structure and semantics of the related data, and the governing business rules ensuring valid execution. In addition, all defined data elements are aligned with the eProcurement Ontology (ePO) to achieve semantic interoperability and consistent representation across procurement systems. This document is linked to Directive 2014/24/EC on public procurement [8], Directive 2014/25/EC on procurement by entities operating in the water, energy, transport and postal services sectors [9], Directive 2014/23/EC on the award of concession contracts [10] and Directive 2009 /81/EC on the coordination of procedures for the award of contracts in the fields of defence and security [11]. Implementing Regulation (EU) 2019/1780 establishing standard forms for the publication of notices [eForms] [12] and Implementing Regulation (EU) 2016/7 establishing the standard form for the European Single Procurement Document [ESPD] [13] are supplementary regulations that are relevant to this document. The identifier of this choreographies document is EN 17014-1:2026.

Total records found: 258
arrow-prev 1 2 3 4 5 6 11 arrow-next

Quick filters

ICS
Vandenilio technologijos (3) Kiti su dirvožemio kokybe susiję standartai (1) Biologinės dirvožemio savybės (1) Advanced ceramics (1) Aerospace electric equipment and systems (2) Agricultural machines and equipment in general (1) Alarm and warning systems (1) Alkaline secondary cells and batteries (4) Aluminium products (2) Anaesthetic, respiratory and reanimation equipment (4) Automatic controls for household use (2) Binders. Sealing materials (2) Body care equipment (1) Bolts, screws, studs (1) Brazing and soldering (1) Cables (1) Cableway equipment (1) Cereals, pulses and derived products (3) Chemical analysis of metals (1) Chemical laboratories. Laboratory equipment (1) Components and accessories in general (1) Components for rotating machines (1) Construction of railways (1) Copper products (1) Corrosion of metals (1) Crash protection and restraint systems (5) Dental instruments (1) Dental materials (5) Domestic safety (1) Earthworks. Excavations. Foundation construction. Underground works (2) Electric furnaces (2) Electric heaters (1) Electric tools (1) Electrical and electronic equipment (1) Electrical engineering in general (1) Electricity supply systems (2) Electroacoustics (1) Electronics (Vocabularies) (1) Explosives. Pyrotechnics and fireworks (6) Fertilizers (10) Fibre optic interconnecting devices (2) Fibres and cables (5) Finances. Banking. Monetary systems. Insurance (1) Fissile materials and nuclear fuel technology (1) Fluid systems and components for general use (Vocabularies) (1) Footwear (1) Fruits and derived products (2) Fuses and other overcurrent protection devices (7) Gas supply systems (1) Gases for industrial application (1) Geology. Meteorology. Hydrology (1) Geometrical Product Specification (GPS) (1) Glass in building (1) Heat pumps (1) Hoses and hose assemblies (1) Ignitability and burning behaviour of materials and products (1) Immunity (2) Indoor sports equipment (2) Information technology (IT) in general (3) Inland navigation vessels (1) Insulation systems (1) IT applications in building and construction industry (1) IT applications in health care technology (2) IT applications in trade (3) IT Security (11) Ladders (1) Laminated sheets (1) Leather and furs (2) Leisure and tourism in general (1) Lifts. Escalators (1) Low voltage switchgear and controlgear (3) Maintenance services. Facilities management (1) Materials and articles in contact with foodstuffs (2) Medical equipment in general (1) Medical microbiology (1) Noise emitted by machines and equipment (1) Non-destructive testing (3) Non-destructive testing of metals (1) Non-ferrous alloys in general (1) Nuclear power plants. Safety (1) Organic coatings (1) Other wood-based panels (1) Outdoor and water sports equipment (1) Paints and varnishes (1) Paper and board (2) Petroleum products in general (2) Pipeline components and pipelines in general (4) Plastics pipes (1) Pollution, pollution control and conservation (2) Power transmission and distribution networks in general (1) Pressure regulators (2) Properties of surfaces (1) Public buildings (1) Pumps and motors (1) Railway engineering in general (1) Reactor engineering (1) Rectifiers. Converters. Stabilized power supply (1) Recycling (1) Road construction (1) Rotating machinery in general (2) Safety of machinery (5) Semiconductor devices in general (3) Services for companies (1) Services for consumers (1) Small craft (2) Small kitchen appliances (1) Software (1) Solar energy engineering (1) Solid fuel heaters (1) Solid fuels (1) Steels (1) Sterilized packaging (4) Sterilizing equipment (1) Surface preparation (1) Switches (1) Syringes, needles and catheters (2) Technical product documentation (1) Telecommunications in general (1) TELECOMMUNICATIONS. AUDIO AND VIDEO ENGINEERING (11) Telecontrol. Telemetering (7) Test conditions and procedures in general (1) Textile fibres in general (1) Trade. Commercial function. Marketing (1) Trailing stock (1) Transfusion, infusion and injection equipment (3) Ventilation and air-conditioning systems (1) Ventilators. Fans. Air-conditioners (1) Water heating equipment (1) Waxes, bituminous materials and other petroleum products (2) Welding, brazing and soldering in general (1) Woodworking machines (1)